Another ACPI testing script I wrote (/modified the existing one) for more than one battery, and integration in existing suspend scripts (i.e. the Ubuntu suspend system)
most people will go fine with the original, just for the case someone prefers support for more than one battery. I'm not quite sure if the results will be exact for multiple Batteries, since I experience an extra drain when my Thinkpad is switching.
Part 1 must be executed before suspending, Part 2 afterwards.
Part 1:
#!/bin/sh # test script for measuring power drain during suspend-to-ram with ACPI # execute before suspend # in ubuntu: save in /etc/acpi/suspend.d/ # default settings, change if needed LOG=/var/log/battery.log DATEFILE=/tmp/BATTESTDATE BATFILE=/tmp/BATTESTLOAD # save system time hwclock --systohc # get start values date >> $LOG DATE_BEFORE=`date +%s` echo $DATE_BEFORE >$DATEFILE #get battery states BAT_BEFORE=0 BATS_DISCHARGING=0 for b in /proc/acpi/battery/*; do CBAT=`grep 'remaining capacity' $b/state | awk '{print $3}'` BAT_BEFORE=`echo "$BAT_BEFORE + $CBAT" |bc` if grep -q '^charging state:.*discharging' $b/state; then BATS_DISCHARGING=`echo "$BATS_DISCHARGING + 1" |bc` fi done echo $BAT_BEFORE >$BATFILE if [ $BATS_DISCHARGING -eq 0 ]; then echo '!!! Not running on battery power while going to sleep!' >> $LOG fi
Part 2:
#!/bin/sh # test script for measuring power drain during suspend-to-ram with ACPI # execute after suspend # in ubuntu: save in /etc/acpi/resume.d/ # default settings, change if needed LOG=/var/log/battery.log DATEFILE=/tmp/BATTESTDATE BATFILE=/tmp/BATTESTLOAD BATTERY=BAT0 THRESHOLD=1000 # restore system time hwclock --hctosys DATE_BEFORE=`cat $DATEFILE` BAT_BEFORE=`cat $BATFILE` rm -f $BATFILE rm -f $DATEFILE # get end values DATE_AFTER=`date +%s` #get battery states BAT_AFTER=0 BATS_DISCHARGING=0 for b in /proc/acpi/battery/*; do CBAT=`grep 'remaining capacity' $b/state | awk '{print $3}'` BAT_AFTER=`echo "$BAT_AFTER + $CBAT" |bc` if grep -q '^charging state:.*discharging' $b/state; then BATS_DISCHARGING=`echo "$BATS_DISCHARGING + 1" |bc` fi done if [ $BATS_DISCHARGING -eq 0 ]; then echo '!!! Not running on battery power while waking up!' >> $LOG fi # do the calculations DIFF=`echo "$BAT_AFTER - $BAT_BEFORE" | bc` SECONDS=`echo "$DATE_AFTER - $DATE_BEFORE" | bc` USAGE=`echo "($DIFF * 60 * 60) / ($SECONDS)" | bc` # output the results echo "before: $BAT_BEFORE mWh" >> $LOG echo "after: $BAT_AFTER mWh" >> $LOG echo "diff: $DIFF mWh" >> $LOG echo "seconds: $SECONDS sec" >> $LOG echo "result: $USAGE mW" >> $LOG if [ $USAGE -gt -$THRESHOLD ] then echo "Power drain seems ok" >> $LOG else echo "Power drain seems a little high" >> $LOG fi if [ $SECONDS -lt 1200 ] then echo "!!! The notebook was suspended less than 20 minutes." >> $LOG echo "!!! To get representative values please let the notebook sleep" >> $LOG echo "!!! for at least 20 minutes." >> $LOG fi echo "" >> $LOG