|           for temp in `sed s/temperatures:// < /proc/acpi/ibm/thermal` |           for temp in `sed s/temperatures:// < /proc/acpi/ibm/thermal` | ||
|             do |             do | ||
| − |               test $temp -gt $SWITCHTEMP | + |               test $temp -gt $SWITCHTEMP && fan=yes | 
| + |            done | ||
| + | |||
| + |          if [ "$fan" = "yes" ]; then | ||
| + |            command='enable' | ||
| + |            SWITCHTEMP=`expr $MAXTEMP - $DELTA` | ||
| + |          else | ||
| + |            SWITCHTEMP=$MAXTEMP | ||
| + |            command='disable' | ||
| + |          fi | ||
| + |         else # ac-adapter on -> set fan control to standard behaviour | ||
| + |          command='enable' | ||
| + |        fi | ||
| + | |||
| + |        echo $command > /proc/acpi/ibm/fan | ||
| + |        sleep 15 | ||
| + |      done  | ||
| + |   done | ||
Revision as of 15:24, 11 April 2007
- !/bin/sh
- fan control-script
- based upon ibm-acpi 0.11 (experimental=1 !)
- eliminates anoying "fan always on" in battery mode
- works with hysteresis (DELTA) so that always-turn-on/turn-off is avoided
- fan acivates at MAXTEMP and cools down CPU, GPU etc. to MAXTEMP-DELTA than the fan is turned off
- furthermore detects if AC is on and gives back fan control to default behaviour than
- one can change MAXTEMP and DELTA to individual values
- but take care of your THINKPAD don`t melt it!
- have fun!
- mk 05.05.05
MAXTEMP=51 DELTA=4
SWITCHTEMP=$MAXTEMP
- make sure the script doesn't leave the fan off on error
trap "echo enable > /proc/acpi/ibm/fan" EXIT
while [ 1 ]; do
 for ac in `sed s/state:// < /proc/acpi/ac_adapter/AC/state`
   do
    if [ "$ac" = "off-line" ]; then
        fan=no
        for temp in `sed s/temperatures:// < /proc/acpi/ibm/thermal`
          do
            test $temp -gt $SWITCHTEMP && fan=yes
          done
        if [ "$fan" = "yes" ]; then
          command='enable'
          SWITCHTEMP=`expr $MAXTEMP - $DELTA`
        else
          SWITCHTEMP=$MAXTEMP
          command='disable'
        fi
       else # ac-adapter on -> set fan control to standard behaviour
        command='enable'
      fi
      echo $command > /proc/acpi/ibm/fan
      sleep 15
    done 
 done